IEA705I: ERROR: ERROR DURING GETMAIN SYS CODE = 878-10

Technote (troubleshooting)


Problem(Abstract)

IEA705I: ERROR: ERROR DURING GETMAIN SYS CODE = 878-10

Cause

Not enough virtual private area to satisfy the request. Causing memory
fragmentation because system not recycled often enough, or region size is too
small

Resolving the problem

1) Bounce Connect:Enterprise on a scheduled basis to clean up any fragmentation.
2) Increase the Region size (min of 5M). This depends on size of VSAM files & number processes in one step.

Historical Number

PRI9290

Rate this page: