Troubleshooting
Problem
Error stating that the tempdb is full when attempting to open the Audit log
Symptom
Error states that the tempdb is full when attempting to open the Audit log.
Gentran Audit log will not open
Cause
Too many items in the ProcAuditLog_tb. This could be caused by a lack of maintenance on the audit log or by a process that went into a loop and filled the ProcAuditLog_tb with a large number of messages.
Resolving The Problem
First purge the audit log with one of these methods:
- Run a GDW_Audit_Purge or
- Open Gentran:Server Configuration > click the Audit/Notification tab > click the Purge button.
If neither of these methods works, see Unable to view or purge Audit Log for steps to purge the audit log using SQL Queries.
[{"Product":{"code":"SS6V3G","label":"Sterling Gentran:Server for Microsoft Windows"},"Business Unit":{"code":"BU055","label":"Cognitive Applications"},"Component":"Not Applicable","Platform":[{"code":"PF033","label":"Windows"}],"Version":"5.1;5.2;5.3;5.3.1","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Historical Number
PRI664;SCI50246