IBM Support

CONNECT:Direct UNIX Runtask/Runjob Not Executing (SCI19129)

Troubleshooting


Problem

CONNECT:Direct UNIX Runtask/Runjob Not Executing (SCI19129)

Symptom

Error: Retrun Code 127
Error: XSMG402I A user RUNTASK step completed.
Error: Return code7F
Restricted Shell

Cause

has specified a directory value in the pstmt.run_dir parm in the userfile.cfg
file.

Resolving The Problem

1) When specifying a directory value in the pstmt.run_dir parm, this will cause
the UNIX restricted shell to be invoked, providing enhanced security. If this
is preferred, the customer must understand the concepts of restricted shell
environments and usage.

Please review the CONNECT:Direct for UNIX Administration (Maintaining the
User Authorization Information File) for further details on the limitations
and usage when using CONNECT:Direct for UNIX.

2) The customer may remove the directory which will remove the restriction and
allow the customer to use the command. If no program directory is not
specified, the regualar (Bourne) shell is invoked for executing commands.

[{"Product":{"code":"SSFVK3","label":"IBM Sterling Connect:Enterprise for UNIX"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Component":"Not Applicable","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"All","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]