BMR restore failure with "FBSP7024E FastBack BMR restore finished with exit code [-1]."

Technote (troubleshooting)


Problem(Abstract)

FastBack BMR restore terminates with the following message box.
"FBSP7024E FastBack Bare Machine Recovery finished with exit code [-1]"

Symptom

When FastBack BMR restore is in progress, it may suddenly terminates with the following message, then BMR restore fails.

"FBSP7024E FastBack Bare Machine Recovery finished with exit code [-1]"


Cause

The error happens in case BMR fails to allocate memory.

A customer encountered this problem when he started BMR boot CD on the target machine with 384MB memory. According to FastBack BMR User's Guide, the FastBack for Bare Machine Recovery CD requires a minimum of 512 MB of RAM.


Environment

FastBack BMR 5.5 or 6.1

Resolving the problem

Allocate at least 512MB physical memory for the target machine. More memory might be required in some cases.

Rate this page:

(0 users)Average rating

Add comments

Document information


More support for:

Tivoli Storage Manager FastBack for Bare Machine Recovery

Software version:

5.5, 6.1

Operating system(s):

Windows

Reference #:

1512647

Modified date:

2014-02-27

Translate my page

Machine Translation

Content navigation