BMR restore failure with "FBSP7024E FastBack BMR restore finished with exit code [-1]."

Technote (troubleshooting)


Problem(Abstract)

FastBack BMR restore may terminate with the following message box.
"FBSP7024E FastBack Bare Machine Recovery finished with exit code [-1]"

Symptom

When FastBack BMR restore is in progress, it may terminate with the following message, then BMR restore fails.

"FBSP7024E FastBack Bare Machine Recovery finished with exit code [-1]"


Cause

The error occurs in case BMR fails to allocate memory.

A use encountered this problem when he started BMR boot CD on the target machine with 384MB memory. According to FastBack BMR User's Guide, the FastBack for Bare Machine Recovery CD requires a minimum of 512 MB of RAM.


Environment

FastBack BMR 6.1

Resolving the problem

Allocate at least 512MB physical memory for the target machine. More memory might be required in some cases.