Question & Answer
Question
Is there a reason that PMs are not being created when rotating assets are transferred?
Answer
Currently when a rotating item is associated to a PM and that rotating item is transferred to a new site, Maximo creates a new PM record in the new site. This functionality will only work when the corresponding PM's status is active. If the PM record is in a status of draft, this will not apply and the PMs will not be created once moved to the new site. This is currently working as designed and is not a bug. For the records to be created based on the move, the status of the PM must be active.
[{"Product":{"code":"SSLKT6","label":"IBM Maximo Asset Management"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Component":"Prev Maint","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"Version Independent","Edition":"All Editions","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Was this topic helpful?