zSecure Command Verifier 1.12 SMP/E ACCEPT fails with IEW2454W

Technote (troubleshooting)


Problem(Abstract)

Attempts to SMP/E ACCEPT result in RC=12 when using IBM Tivoli zSecure Command Verifier 1.12.

Symptom

In addition to the SMP/E ACCEPT RC=12, the following link edit messages are seen:

z/OS V1 R11 BINDER 10:05:21 FRIDAY APRIL 15, 2011
BATCH EMULATOR JOB(CV12ACCE ) STEP(ACCEPTC ) PGM= HEWL
IEW2278I B352 INVOCATION PARAMETERS - NCAL,LIST,SIZE=(2048K,128K),NCAL
IEW2322I 1220 1 INCLUDE SMPWRK3(C4RUCATT) UA58084 SEQ # 000005
IEW2322I 1220 2 IDENTIFY C4RUCATT('UA58084')
IEW2322I 1220 3 SETSSI 01118084
IEW2322I 1220 4 NAME C4RUCATT(R) MAX ACCEPTABLE RC=00
IEW2454W 9203 SYMBOL C4RSMSG UNRESOLVED. NO AUTOCALL (NCAL) SPECIFIED.
IEW2454W 9203 SYMBOL C4R#RACR UNRESOLVED. NO AUTOCALL (NCAL) SPECIFIED.
IEW2650I 5102 MODULE ENTRY NOT PROVIDED. ENTRY DEFAULTS TO SECTION C4RUCATT.


Diagnosing the problem

Check the SMP/E OPTIONS settings for utility HEWL - it must be set to at least 4 in order for the ACCEPT to complete successfully.


Resolving the problem

Change the SMP/E OPTION parameter for HEWL to at least 4.

Supplied job C4RJSMPA has been modified in post 1.12 releases of zSecure Command Verifier to do this setting properly.