IBM Support

ABEND0D6 RC 26 during Telnet processing

Troubleshooting


Problem

ABEND0D6 RC 26 occurs after Telnet client attempts a connection.

Symptom

MVS TCP/IP TELNET CS V1R11                                  
IEA995I SYMPTOM DUMP OUTPUT                                
SYSTEM COMPLETION CODE=0D6  REASON CODE=00000026            
TIME=09.30.48  SEQ=00134  CPU=0000  ASID=0047              
PSW AT TIME OF ERROR  078D0E00   0011E0FC  ILC 4  INTC 26  
ACTIVE LOAD MODULE ADDRESS=000A5000 OFFSET=000790FC        
NAME=TELNET                                                
DATA AT PSW 0011E0F6 - F01C5040 D00CB218 200058E0          
GR 0: 0009BB00 1: 0009BE10                                  
2: 7FFFF000 3: 0011B398                                    
4: 00000047 5: 40000000                                    
6: 0009B520 7: 0009B740                                    
8: 0011DCF8 9: 0009BD48  

A: 0011ECF7 B: 0009B010                                  
C: 00099000 D: 0009BCB0                                  
E: 0011E0D8 F: 00000000                                  
END OF SYMPTOM DUMP                                      
Abend 0D6000 hex occurred processing command 'TELNET '.  
ISPD210 CMD abended - 'TELNET' terminated abnormally.

Diagnosing The Problem

The ABEND0D6 PIC 26 is taken in module MVPCDOVM, the client interface for the Virtual Machine Communication Facility (VMCF), on a program call (PC) instruction x'B2182000'. MVPCDOVM was attempting a PC to VMCF at the time of the error. VMCF, however, was not active at the time, as the IP SELECT ALL output indicates.

Resolving The Problem

You must have VMCF and the Termination Notification Facility (TNF) active before the Telnet client attempts a connection. The TELNET command is a TSO Telnet client command which requires this interface to be active to work.

[{"Product":{"code":"SSSN3L","label":"z\/OS Communications Server"},"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Component":"--","Platform":[{"code":"PF035","label":"z\/OS"}],"Version":"1.10;1.11;1.12;1.13;2.1;2.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
15 June 2018

UID