Troubleshooting
Problem
You are trying to LOAD historical data to your CICS Performance Analyzer for z/OS (CICS PA) HDB dataset and you receive the following error messages when you submit the job: CPA0219I End of File processing for SMF File SMFIN001 has started CPA0233E Dynamic Allocation failed. RC=08 Error=035C Info=0002 from module CPAHDLBA/HDBL0001 IKJ56231I UTILITY DATA SET NOT ALLOCATED, SYSTEM OR INSTALLATION ERROR+ IKJ56231I TEXT UNIT X'0002' CONTAINS INVALID PARAMETER CPA0229I CICS PA has completed processing, RC=8
Symptom
CPA0233E Dynamic Allocation failed. RC=08 Error=035C Info=0002 from module CPAHDLBA/HDBL0001
Cause
You have single quotes around the DSN Prefix, for example:
Resolving The Problem
Remove the single quotes from the DSN Prefix, for example 'ONTOP.CARLIN', and rerun the HDB Load job.
Product Synonym
CICSPA CICS PA