How do you connect to a Proventia Network Security Controller (PNSC) or Proventia Network Active Bypass (PNAB) using a serial cable?
Answer
The Proventia Network Security Controller (PNSC) and Proventia Network Active Bypass (PNAB) appliances use serial interface settings that are different than those used by other Proventia appliances. This article lists the settings necessary to connect to a PNSC or PNAB appliance with a serial cable.
Here is how to configure the serial connection:
- Connect a serial cable from a local PC to the Proventia Network Security Controller.
- Configure a terminal emulator with the following settings:
Bits per second: 115,200
Data bits: 8
Parity: N
Stop: 1
Flow Control: None
Emulation: VT100
(for more information, refer to the Proventia Network Security Controller User Guide) - You should now be able to see output from the Network Security Controller on your terminal emulator. If you cannot, please verify the network security controller is plugged in and the serial cable is properly connected.
___________________________________________________________________________
If the above information does not resolve your issue, please contact IBM Security Solutions Customer Support.
| Segment | Product | Component | Platform | Version | Edition |
|---|---|---|---|---|---|
| Security | Proventia Network Active Bypass | Not Applicable | |||
| Security | Proventia Network Active Bypass | Firmware | 1.0 |
Historical Number
5907
Product Alias/Synonym
Proventia Network Security Controller
Proventia Network Active Bypass
Rate this page:
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.