IBM Support

How to use Rational Functional Tester to test oracle form and generic IE application

Troubleshooting


Problem

This technote describes how to test between Oracle forms and a Microsoft Internet Explorer (IE) application using IBM Rational Functional Tester.

Symptom

After apply the workaround to test Oracle form with Rational Functional Tester: JavaPluginID and JavaPluginVerIndependent, Rational Functional Tester can not test on regular IE application

Cause

Rational Functional Tester is using the jinitiator JRE instead of regular JRE for the browser at this time.

Resolving The Problem

User needs to remove the above two registry keys, JavaPluginID and JavaPluginVerIndependent, then Rational Functional Tester will be able to test general IE application again.



[{"Product":{"code":"SSJMXE","label":"IBM Rational Functional Tester"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Component":"Test Execution","Platform":[{"code":"PF033","label":"Windows"}],"Version":"7.0;7.0.0.1;7.0.0.2;7.0.1;7.0.1.1;7.0.1.2;7.0.1.3;8.0;8.0.0.1;8.0.0.2;8.0.0.3;8.1;8.1.0.1;8.1.0.2","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]