ODBC driver could not be loaded due to system error code 193

Technote (troubleshooting)


Problem(Abstract)

Unable to use the Microsoft ODBC Administrator to create the DataSource on Windows 64-bit.

Symptom

Receive the error

"The setup routines for the DataDirect 5.3 <driver name> ODBC driver could not be loaded due to system error code 193."

Cause

The driver is a 32-bit driver and the default Microsoft ODBC Administrator utility is for 64-bit drivers.

Resolving the problem

On 64-bit Windows, there are two versions of the Microsoft ODBC Administrator tool. Typically, you go to Start --> Administrative Tools --> Data Sources (ODBC) to create ODBC connections. This calls the program %WINDIR%\System32\odbcad32.exe to create a 64-bit ODBC connection. However, this program will not create 32-bit ODBC connections.

The ODBC gateway requires a 32-bit ODBC connection. Use the 32-bit version of the Microsoft ODBC Administrator tool located in %systemdrive%\Windows\SysWoW64\odbcad32.exe to create the ODBC Data Source.