Troubleshooting
Problem
PowerPlay Transformer 7.0 Windows NT Description: When building a large cube, say 500 MB, the following error message is displayed: Error : TR0120 Transformer can't write to a file. Solution: This error may occur even when the Temporary Directories in the Configuration Manager have been set to a drive without sufficient space. In the Configuration Manager the List of Temporary Directories is set under Services > UDA > General. If the datasource is an Impromptu Query Definition (IQD) file, the temp space which will be used to execute some functions and/or sorting will be the one defined in user and system environment variables. To correct this, change the user and system variables in the Control Panel > System > Environment Variables to a drive that has enough space.
Resolving The Problem
This error may occur even when the Temporary Directories in the Configuration Manager have been set to a drive without sufficient space. In the Configuration Manager the List of Temporary Directories is set under Services > UDA > General. If the datasource is an Impromptu Query Definition (IQD) file, the temp space which will be used to execute some functions and/or sorting will be the one defined in user and system environment variables. To correct this, change the user and system variables in the Control Panel > System > Environment Variables to a drive that has enough space.
Historical Number
123601
Was this topic helpful?
Document Information
Modified date:
28 November 2022
UID
swg21337924