IBM Support

ClearCase option to compare with previous version results in BSOD

Troubleshooting


Problem

This technote identifies an issue that can occur where comparing with previous version in IBM Rational ClearCase (CC) results in a Blue Screen (BSOD) when Entrust Group Share 1.0 or 1.0.1 is installed.

Symptom


Using the Compare with previous version option in ClearCase results in a BSOD. 

Cause


Entrust Group Share 1.0 or 1.01  is installed on the system.  This software uses a minifilter driver.

This issue has been identified as a product defect under APAR PK51651.

Diagnosing The Problem

The stack trace error is:


    BAD_POOL_CALLER (c2)

The current thread is making a bad pool request.  Typically this is at a bad IRQL level or double freeing the same allocation, etc.

Resolving The Problem


Defect APAR PK51651 has been resolved in ClearCase 7.0.0.8 and 7.0.1.7

No workaround is available.

[{"Product":{"code":"SSSH27","label":"Rational ClearCase"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Component":"Application Conflicts","Platform":[{"code":"PF033","label":"Windows"}],"Version":"7.0.0.1;7.0.0.2;7.0.0.3;7.0.1;7.0.1.1;7.0.1.2","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]