IST985I USER EXIT ISTEXPRF REPLACEMENT FAILED-CODE F2

Technote (FAQ)


Question

ISTEXPRF replacement failed code F2 error message occurs at NetView Performance Monitor (NPM) startup. Also, FNM305T ISTEXPRF NOT LOADED, RC=24 may occur.

Answer

At startup, NPM issues a command to VTAM requesting VTAM to load ISTEXPRF load module. In order to be able to then execute this module, the library it was loaded from must be authorized. Generally, the NPM LLIB is authorized and if the VTAM start proc points to that in its llib concatenation it will load properly. If the exit is moved to an unauthorized library the following messages may occur.

.
IST985I USER EXIT ISTEXPRF REPLACEMENT FAILED-CODE F2
FNM305T ISTEXPRF NOT LOADED, RC=24
FNM930I NPM COMMAND PROCESSING TERMINATED
FNM320I FNMCCT00 ENDED, RC=00000
FNM320I FNMVDC00 ENDED, RC=00000
FNM320I FNMONL00 ENDED, RC=00016
FNM320I FNMSDC00 ENDED, RC=00000
FNM320I FNMFST00 ENDED, RC=00000
FNM320I FNMFST00 ENDED, RC=00000
IEF404I NPM - ENDED - TIME=11.28.29