RS01226: SCAAUTOMATION DATASTORE SYNCHRONIZE REPORTS SUCCESS WHEN IT ACTUALLY FAILS

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

APAR status

  • Closed as program error.

Error description

  • DataStore Synchronization does not fail when one of the datasync
    tasks fails.  It continues through all the tasks and reports
    success at the end.
    
    Business Impact: If the DataStore Synchronization reports
    success, other jobs will continue to run without knowing there
    was a problem.  The process should report failure immediately
    when any of the tasks fail.
    
    Version 7.6 of IPFA contains the fix for this defect but it is
    needed in version 7.5 as well.
    
    1. Locate ScaAutomation.DataStoreSynchronize.exe in the
    ScaAutomation folder.
    2. Open a command window and run
    ScaAutomation.DataStoreSynchronize.exe from the command line
    with the following arguments (substituting proper user
    credentials and URL for Integration Services.Make sure one of
    the tasks fails):
    
    ScaAutomation.DataStoreSynchronize.exe /l:"userName"
    /a:"password" /i:"http://localhost" /sd:"Master Data Store"
    
    3. See that the status of each task is reported. If one of the
    tasks fail, the following tasks continue to run and the process
    always reports success.
    

Local fix

  • There is no work around.
    

Problem summary

  • This issue has been resolved and fix will be available on an
    as-needed basis.
    

Problem conclusion

  • A new ScaAutomation.DataStoreSynchronize.exe file has been
    created for 7.5.x users.
    

Temporary fix

Comments

APAR Information

  • APAR number

    RS01226

  • Reported component name

    ILOG INV & PFO

  • Reported component ID

    5725A0400

  • Reported release

    750

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-01-22

  • Closed date

    2013-01-23

  • Last modified date

    2013-01-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ILOG INV & PFO

  • Fixed component ID

    5725A0400

Applicable component levels

  • R750 PSY

       UP

  • R760 PSN