APAR status
Closed as program error.
Error description
If the Reviewed_N value is NULL and the Recommended_N value is equal to zero in a particular record, that change is not recorded in the Audit Log when the recommendation is applied. This is due to an erroneous design assumption that NULL is equivalent to Zero. The tr_OverrideAudit trigger should be altered to remove this equivocation. Steps to reproduce: 1. create a blank master datastore 2. create or import complimentary records in the Staging Product Location Master and Staging Demand Master 3. run table sync 4. create a new scenario through the creation wizard 5. run the optimizer and publish the solution back to the datastore 6. go to the Review and Override table 7. open a record in the Safety Stock Calculator 8. move Recommendation to Adjusted 9. change Demand value to zero 10. calculate and update record 11. the Adjusted Safety Stock value should now be zero 12. select a reason code and the action to Update Changes 13. save the changes 14. check the Audit Log for a Safety Stock record from NULL to zero
Local fix
There is no workaround.
Problem summary
This issue has been resolved and the fix will be available in IBM ILOG Inventory and Product Flow Analyst 7.6.15.4.
Problem conclusion
The fix is now available on FixCentral.
Temporary fix
Comments
APAR Information
APAR number
RS01199
Reported component name
ILOG INV & PFO
Reported component ID
5725A0400
Reported release
760
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-01-14
Closed date
2013-02-08
Last modified date
2013-02-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ILOG INV & PFO
Fixed component ID
5725A0400
Applicable component levels
R760 PSY
UP
R750 PSN
UP
Rate this page:
Average rating
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.