PQ90800: MSGIEC161I 056-084 or MSGIEC161I 062-086 or possible Pointer Err ors may occur if a HALDB Partition wasn't properly closed

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as fixed if next.

Error description

  • 1) Batch updates Partition 1 (checkpoints are taken)...
    2) Batch now update Partition 2 (checkpoints are taken)...>>>
       >>>...Abend...!!!
    3) BBO to last checkpoint in Partition 2 - Partition 1 is not
       touched...
    4) Restart - Job continues in Partition 2, than Partition 3 and
       Batch terminates normal.
    5) Image Copy (IEC... Messages appear...
    6) Database gets accessed in RO Mode only (Online)....
    7) At Online End (end of day) pointer checker shows Pointer
    Errors in Partition 1
    The problem is due to Partition one not being updated anymore
    after the Abend (not opened for update)...
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS V710 using BBO and HALDB.            *
    ****************************************************************
    * PROBLEM DESCRIPTION: A batch DLI receives message IEC161     *
    *                      with RC56 and RC62 after batch backout  *
    *                      BBO on a PHDAM database.                *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    A DLIBATCH doing updates on partition one of a PHDAM data
    base with three partitions. A checkpoint is done. Then more
    updates goes into partition two, halfway through, the job
    abnormally terminated. A batch backout BBO was scheduled.
    Messages MSGIEC161 RC56 and RC62 were issued on the first
    open of partition one.
    .
    The reason of the messages because the first partition
    failed to close properly leaving on the OPEN for OUTPUT
    bit on in the catalog. The next attempt to open the data
    set will cause IEC161I RC56 RSN84. This error will cause
    an implicit verify to be issued by VSAM. If the VERIFY
    is successfull, IEC161I RC84 RSN62 will be issued.
    The IMPLICIT VERIFY only updates the in-core control
    blocks. However, the open for output bit will not be
    turrned off in the catalog.
    .
    All partitions that were open at the time of the ABEND
    should be opened and closed during batch backout. This
    feature is missing from current IMS releases. The fix
    of this APAR goes beyond the scope of an APAR.
    PTM KFN0397 is opened to address this issue.
    

Problem conclusion

Temporary fix

Comments

  • This apar is closed as FIN . The problem reported in this apar
    will be fixed in a future release/version of IMS, tracked by
    PTM# KFN0397 .
    
         FIN  Fixed IF next. There is a deficiency that we
              currently plan to fix if there is another release.
              This is not a commitment, but expresses our
              intention. 'Next Release' is not defined.
    
              PTM KFN0397 IS IMPLEMENTED IN THE BASE CODE OF IMS
              V10.
    

APAR Information

  • APAR number

    PQ90800

  • Reported component name

    IMS V7

  • Reported component ID

    5655B0100

  • Reported release

    700

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2004-06-30

  • Closed date

    2005-01-25

  • Last modified date

    2008-09-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    IMS V7

  • Fixed component ID

    5655B0100

Applicable component levels

  • R700 PSN

       UP



Rate this page:

(0 users)Average rating

Document information


More support for:

IMS

Software version:

700

Reference #:

PQ90800

Modified date:

2008-09-09

Translate my page