A fix is available
APAR status
Closed as program error.
Error description
When running a packaged workspace that uses external routines and user is forced off (ABENDx22), he receives ABEND0C4 in AP2XN11 at displacement X'2E20' in routine X11$MIEX because R9 is pointing to an area already freed.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All APL2 users of Associated Processor 11. * **************************************************************** * PROBLEM DESCRIPTION: An ABEND0C4 can occur if a program * * invoked by Associated Processor 11 * * timesout. ABENDx22 * **************************************************************** * RECOMMENDATION: * **************************************************************** If the abending program does not have an abend exit, control comes to Associated Processor 11 abend exit. As part of handling the abend, the control blocks associated with the program are free'd. Later in the processing, an attempt is made to queue an informational message regarding the abend. This message handling used a field in a control block previously free'd. Hence, ABEND0C4
Problem conclusion
Associated Processor 11 will be corrected to not issue the informational message if the control block required has been free'd. KEYWORDS: ZOS111T/K ZOS112T/K ZOS113T/K ZOS0201T/K
Temporary fix
Comments
APAR Information
APAR number
PN62132
Reported component name
APL2
Reported component ID
566889901
Reported release
212
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
1994-09-06
Closed date
1994-11-16
Last modified date
2012-09-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UN69981 UN69982 UN69983 UN69984
Modules/Macros
AP2TN11 AP2VN11 AP2XN11
Fix information
Fixed component name
APL2
Fixed component ID
566889901
Applicable component levels
R212 PSY UN69981
UP94/11/17 P F411
R215 PSY UN69982
UP94/11/16 I 1000
R222 PSY UN69983
UP94/11/17 P F411
R225 PSY UK07517
UP05/09/23 I 1000
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
Rate this page:
Average rating
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.