Error description

  • Miscellaneous bug fixes.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Fault Analyzer Version 11 users.         *
    ****************************************************************
    * PROBLEM DESCRIPTION: 01. Fault Analyzer RFR dump event list  *
    *                          might be missing events.            *
    *                          APAR PI05473                        *
    *                      02. New History File Allocation dialog  *
    *                          not shown when copying fault entry  *
    *                          to non-existing history file.       *
    *                          APAR PI05474                        *
    *                      03. A Fault Analyzer user is analyzing  *
    *                          a CICS SDUMP, and sees errors in    *
    *                          the DS Domain panels.               *
    *                          APAR PI05475                        *
    *                      04. User is analyzing a CICS TS 3.1     *
    *                          SDUMP and gets an 0C4 abend in      *
    *                          function pp_ke_stack.               *
    *                          APAR PI05476                        *
    *                      05. User gets DFHSR0622 because of      *
    *                          abend 0C4 in CEECGEX.               *
    *                          APAR PI05477                        *
    *                      06. Fault Analyzer IDIS subsystem       *
    *                          IDI0131W messsages ENQ lockout on   *
    *                          history files.                      *
    *                          APAR PI05568                        *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    01. The DSA chaining back through linkage stack entries might
        fail when an invalid backchain address in encountered.
    02. A check for the existence of the target history file was
        missing.
    03. DS panels have incomplete information due to an arbitrary
        limit to the number of internal control blocks that can be
        created. Also, there is a problem in sorting some column
        contents.
    04. pp_ke_stack is processing a stack entry for CICS program
        DFHLEPTQ, which has an invalid (negative) iproc offset.
        This causes pp_ke_stack to abend.
    05. User has issued PURGE of CICS task. FA's IDIXCCEE issues
        EXEC CICS commands in CICSkey and enters WAIT_MVS.
        User issues KILL for task.
        CICS drives LE CEECGEX in USERkey with CICSkey DSA/RSA
        from IDIXCCEE.
    06. APAR PM97968 fixed the 100% CPU loop reported but the
        IDI0131W messages can still occur. This APAR addresses the
        IDI0131W ENQ message not clearing.
    

Problem conclusion

  • 01. The code has been updated.
    02. A check has been added for the existence of the target
        history file.
    03. The number of internal control blocks which can be created
        has been increased. The panel column sort code has been
        fixed.
    04. pp_ke_stack has been modified to handle the bad offset.
    05. IDIXCCEE has been changed to percolate (defer) AEXY abends
        to FA CICS GLUEs, which do not issue EXEC CICS commands
        in a way that can cause the problem.
    06. Code added to correctly retest the ENQ status.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM98461

  • Reported component name

    FAULT ANALYZER

  • Reported component ID

    5655W4600

  • Reported release

    B10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-10-04

  • Closed date

    2013-11-14

  • Last modified date

    2013-12-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI12508

Modules/Macros

  • HADQB10J IDIALLOC IDICAASM IDICABND IDICADYN IDICALE  IDICALOC
    IDICASUB IDICBDB2 IDICCFND IDICISA  IDICNF
    
    ***This field was truncated.  To obtain the full apar record, please contact your local support center.***
    

Fix information

  • Fixed component name

    FAULT ANALYZER

  • Fixed component ID

    5655W4600

Applicable component levels

  • RB10 PSY UI12508

       UP13/11/19 P F311

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B10","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXJAJ","label":"Fault Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B10","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
02 December 2013