  • Closed as program error.

Error description

  • When using a special character like ampersand & in the password,
    the TM1RunTI will error out with below message:??(TM1 API Error)
    SystemServerClientNotFound??Server connection failed??
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All Users                                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See error description.                                       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Upgrade to TM1 10.1 RP1 FP2                                  *
    ****************************************************************
    

Problem conclusion

  • Code Fix
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM97456

  • Reported component name

    TM1 SERVER

  • Reported component ID

    5724W49SE

  • Reported release

    A11

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-09-19

  • Closed date

    2013-11-06

  • Last modified date

    2013-11-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TM1 SERVER

  • Fixed component ID

    5724W49SE

Applicable component levels