PM96390: RAA GIVES AES1005E MESSAGE UNSUPPORTED SYNTAX 'TO', WHEN SCANNING CERTAIN COBOL CODE.

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • RAA 6.1 returns AES1005E message saying unsupported syntax
    'To', when  scanning certain COBOL code.
    

Local fix

  • change instances of "To" to "TO" (i.e. all caps) in the COBOL
    code and then rescan to work around this issue.
    

Problem summary

  • When a comment line ends with a literal indicator (quote or
    apostrophe) in column 72, the following literal string is not
    properly detected.
    

Problem conclusion

  • Corrected the algorithm by ignoring comment lines ending with a
    literal indicator.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM96390

  • Reported component name

    RATL ASSET ANAL

  • Reported component ID

    5724V2700

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-09-04

  • Closed date

    2013-09-04

  • Last modified date

    2013-09-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • cobscan
    

Fix information

  • Fixed component name

    RATL ASSET ANAL

  • Fixed component ID

    5724V2700

Applicable component levels

  • R610 PSY

       UP