IBM Support

PM92028: NATIVE IOS 4.3 APP UNABLE TO CONNECT TO WORKLIGHT 5.0.5.X AND LATER SERVERS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • A native application running on an iOS 4.3 device/simulator is
    unable to communicate with Worklight 5.0.5.x and later servers.
    The same application works correctly when run on iOS 5 or later.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Developers and end users who are trying to run a native iOS  *
    * application in an iOS 4.3 environment, which communicates    *
    * with a Worklight server                                      *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * A native application running on an iOS 4.3 device/simulator  *
    * is                                                           *
    * unable to communicate with Worklight 5.0.5.x and later       *
    * servers.                                                     *
    * The same application works correctly when run on iOS 5 or    *
    * later.                                                       *
    *                                                              *
    * The issue is due to the fact that the processing of HTTP     *
    * header names is case-sensitive in iOS 4.3, but not in later  *
    * versions.                                                    *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * -                                                            *
    ****************************************************************
    

Problem conclusion

  • The code has been fixed so that older versions of iOS function
    correctly.
    
    The fix for this APAR is currently targeted for inclusion in
    fixpack 5.0.6.2.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM92028

  • Reported component name

    WORKLIGHT CONSU

  • Reported component ID

    5725I4301

  • Reported release

    505

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-06-27

  • Closed date

    2013-12-14

  • Last modified date

    2013-12-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WORKLIGHT CONSU

  • Fixed component ID

    5725I4301

Applicable component levels

  • R505 PSY

       UP

  • R506 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSZH4A","label":"IBM Worklight"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"505","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: