PM91594: NESTED @ FUNCTION (@SINCE0) IN CONJUNCTION WITH @OFFSET DOES NOT WORK PROPERLY

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

APAR status

  • Closed as program error.

Error description

  • In my stream I have a filler node with the following expression:
    
    @OFFSET(Val2, @SINCE0(Val2 /= 10))
    
    which produces incorrect results.
    Creating a variable that takes the value of @SINCE0(Val2/=10)
    works;
    

Local fix

  • This issue will be addressed in the next Fix Pack. Please refer
    to the Fix Pack schedule at
    http://www-01.ibm.com/support/docview.wss?uid=swg21599157 for
    information on upcoming Fix Packs.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * This affects all users of IBM SPSS Modeler                   *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * NESTED @ FUNCTION (@SINCE0) IN CONJUNCTION WITH @OFFSET DOES *
    * NOT WORK PROPERLY                                            *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Upgrade to IBM SPSS Modeler 16 Fix Pack 1 in order to        *
    * resolve this problem.                                        *
    ****************************************************************
    

Problem conclusion

  • This problem has been resolved in IBM SPSS Modeler 16 Fix Pack 1
    and future releases.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM91594

  • Reported component name

    SPSS MODELER

  • Reported component ID

    5725A64MD

  • Reported release

    F00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-06-21

  • Closed date

    2014-06-09

  • Last modified date

    2014-06-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    SPSS MODELER

  • Fixed component ID

    5725A64MD

Applicable component levels

  • RF00 PSN

       UP

  • RF00 PSY

       UP

  • RG00 PSN

       UP

  • RG00 PSY

       UP



Rate this page:

(0 users)Average rating

Document information


More support for:

SPSS Modeler
Modeler

Software version:

15.0

Reference #:

PM91594

Modified date:

2014-06-09

Translate my page

Machine Translation

Content navigation