A fix is available
APAR status
Closed as program error.
Error description
Miscellaneous bug fixes.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Fault Analyzer Version 12 users. * **************************************************************** * PROBLEM DESCRIPTION: 01. IBM Fault Analyzer IDI0095W * * Unexpected condition IDIDODSN:360 * * when exiting interactive analysis * * of an MVS dump. * * APAR PM95324 * * 02. IDI0095W Unexpected condition found * * in IDISUPDI:1426: IDISUPDI:1851 * * :1426 dup time precedes * * fault entry. * * APAR PM95325 * * 03. Listing exit issues IDISF messages * * when exit returns a SYSDEBUG dsn. * * APAR PM95326 * * 04. COBOL ODO table has incorrect * * stride. * * APAR PM92323 * * 05. After scrolling Fault Entry List * * display right, abend code * * explanation is shown instead of * * processing line command. * * APAR PM92577 * * 06. Language Environment heap analysis * * errors not indicated in the * * Synopsis section of the report. * * APAR PM92984 * * 07. Changes in CICS parm TRTRANSZ for * * CICS/TS 4.2 and 5.1 does not * * increase number of trace entries * * gathered by Fault Analyzer. * * APAR PM95327 * * 08. Lock flag incorrectly reset after * * fault entry interactive reanalysis * * when Enter is pressed on exit to * * save changes to user data. * * APAR PM93221 * * 09. Loop during abend analysis leading * * to IDI0005S message. * * APAR PM95067 * * 10. Fault Analyzer's CICS SDUMP * * "SM ECDSA Subpool Summary" panel * * displays some incorrect or unclear * * values, * * APAR PM93127 * * 11. Abend S0C4 in formatSummary at * * statement 531 compile unit offset * * X'199E'. * * APAR PM95323 * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** 01. When completing an interactive reanalysis of an MVS SVC or SYSMDUMP, the write minidump process might issue IDI0095W from IDIDODSN:360. 02. IBM Fault Analyzer CICS fast duplicate processing might record a vendor altered start time rather than the wall-clock time, even when the UseIDISTime option is set. 03. Listing exit fails to process a SYSDEBUG, then attempts to process it as a compiler listing. 04. ODO recalibration includes redefinitions which causes data item length to be added again. 05. When a point-and-shoot field, such as the "Abend" column field, is scrolled to logically overlap with the line command field, then the point-and-shoot field is incorrectly processed instead of the line command. 06. The specific Language Environment heap analysis errors found in this case had not been made eligible for identification in the report Synopsis. 07. The value of TRTRANSZ was being incorrectly determined and hence a default value of 64K was always being used by Fault Analyzer. 08. The fault entry lock flag was being managed, both in the fault entry member, and in the history file cache, causing incorrect updates. 09. FA code was not allowing for an LE CIB next pointer to be pointing to itself. Hence, FA went into a loop which eventually exhaused all storage and gave a IDI0005S message. 10. Some values are being obtained from the wrong place. Some values are correct but are displayed in hex, while the CICS VerbExit displays them in decimal. 11. An uninitialized variable was used.
Problem conclusion
01. The logic has been changed to handle the allocation condition. 02. Code updated to accommodate date/time alteration test products in the CICS fast duplicate recording process. 03. Listing exit now correctly processes SYSDEBUG files. 04. Only the original definition is inlcuded in recalibration of ODO tables. 05. An error determining the line offset in displays with a non-scrollable section on the left has been fixed. 06. All Language Environment heap analysis errors are now being identified in the Synopsis with a reference to detailed information about the errors in the Language Environment heap analysis section of the report. 07. The correct value of TRTRANSZ is now determined and used accordingly. 08. The fault entry lock flag is now only being managed in the history file cache. 09. Loop detection code added. 10. Fault Analyzer has been changed to display the correct values, and to display both hex and decimal values where appropriate. 11. A check has been added to prevent the use of the uninitialized variable.
Temporary fix
Comments
FIXCAT keywords: COB0501T/K Support for Enterprise COBOL version 5 has been added.
APAR Information
APAR number
PM91555
Reported component name
FAULT ANALYZER
Reported component ID
5655W6900
Reported release
C10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2013-06-20
Closed date
2013-08-21
Last modified date
2013-09-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK96928
Modules/Macros
HADQC10J IDICAASM IDICABND IDICALE IDICALOC IDICASUB IDICCFND IDICISA2 IDICOPYR IDICRXDX IDICRXEI IDICRXET IDICRXHC IDICSMF IDICSPC IDICUXCS IDICUXWR IDIDA IDIDATSA IDIDATST IDIGMAIN IDIGWEB IDIHPMSG IDIMCICS IDINDEX IDIPBRWS IDIPDDIR IDIPDSCU IDIPH129 IDIPH130 IDIPH236 IDIPH237 IDIPH238 IDISAMAN IDISAQUE IDISCJST IDISDB2P IDISDB2S IDISFPEX IDISIFND IDISJAX IDISJL IDISJLD IDISJLOG IDISLKUP IDISLOG IDISMAIN IDISREG IDISRFRA IDISRFRD IDISTIME IDISUPDI IDISVIEW IDISWRAP IDIUTIL IDIWH001 IDIWP002 IDIXALOG IDIXAPI IDIXASUB IDIXCCEE IDIXCC52 IDIXCEE IDIXCE53 IDIXCE67 IDIXCE68 IDIXCM53 IDIXCM67 IDIXCM68 IDIXCX52 IDIXCX53 IDIXDCAP IDIXDSAC IDIXDUMP IDIXFA IDIXGSPC IDIXGSPS IDIXJAVA IDIXOPT IDIXSNAP
Fix information
Fixed component name
FAULT ANALYZER
Fixed component ID
5655W6900
Applicable component levels
RC10 PSY UK96928
UP13/08/28 P F308
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C10","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXJAJ","label":"Fault Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C10","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: