Error description

  • The module in question contains a string $(NCLIBMDLL) in the
    export table for one of the forwarded exports. This reference
    can't be resolved by system loader, but apparently it does not
    care and loads the module with unresolved reference anyway.
    Purify probably shouldn't generate instrumentation error in this
    case.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The module in question contains unresolvable forwarded
    exports, which cause Purify to generate an instrumentation
    error.
    

Problem conclusion

  • Fixed Purify instrumentation engine to not generate an
    instrumentation error if forwarded exports can not be
    resolved. This matches the behavior of the system loader
    which does not treat it as an error.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM90906

  • Reported component name

    PURIFY WIN

  • Reported component ID

    5724G2201

  • Reported release

    701

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-06-11

  • Closed date

    2013-08-08

  • Last modified date

    2013-08-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    PURIFY WIN

  • Fixed component ID

    5724G2201

Applicable component levels

  • R701 PSN

       UP



Rate this page:

(0 users)Average rating

Document information


More support for:

Rational Purify

Software version:

7.0.1

Reference #:

PM90906

Modified date:

2013-08-08

Translate my page

Machine Translation

Content navigation