PM90781: INCORRECT CONFIGURATION OF DB2 DATASOURCE BY INSTALLATION MANAGER MAY CAUSE FWLSE0101E EXCEPTION.

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Using DB2 datasource configuration set up by Installation
    Manager, application may encounter exceptions of the form:
    
    FWLSE0101E: Caused by: <openjpa-1.2.2-r422266:898935 nonfatal
    general error>
    org.apache.openjpa.persistence.PersistenceException:
    [jcc][t4][10120][10898][3.51.90] Invalid operation: result set
    is closed. ERRORCODE=-4470, SQLSTATE=null
    

Local fix

  • Issue may be worked around by setting these custom properties
    in the DB2 datasource configuration:
    
    nonTransactionalDataSource=true
    resultSetHoldability=1
    webSphereDefaultIsolationLevel=2
    
    However, this workaround does not work when using an XA
    datasource.  There are no known workarounds available for that
    case.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Administrators and developers working in a Worklight Server  *
    * environment involving WebSphere Application Server and DB2   *
    * with applications that use push notifications and connect to *
    * DB2 as a data source.                                        *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Using Worklight Server 5.0.5, WAS 7.0 fix 27, and DB2 9.7,   *
    * results in error with a subscribed user is sent a push       *
    * notification:                                                *
    *    [3/13/13 11:31:05:264 IST] 0000001e InvocationCon E       *
    * logError FWLSE0099E: An error occurred while invoking        *
    * procedure CityPulseCore/submitNotificationFWLSE0100E:        *
    * parameters:{                                                 *
    * "arr": [                                                     *
    * "({usersIds: [\"lior1\"], badge: 2})"                        *
    * ]                                                            *
    * }                                                            *
    * [jcc][t4][10120][10898][3.51.90] Invalid operation: result   *
    * set is closed. ERRORCODE=-4470, SQLSTATE=null; nested        *
    * exception is <openjpa-1.2.2-r422266:898935 nonfatal general  *
    * error> org.apache.openjpa.persistence.PersistenceException:  *
    * [jcc][t4][10120][10898][3.51.90] Invalid operation: result   *
    * set is closed. ERRORCODE=-4470, SQLSTATE=null                *
    * FWLSE0101E: Caused by: <openjpa-1.2.2-r422266:898935         *
    * nonfatal general error>                                      *
    * org.apache.openjpa.persistence.PersistenceException:         *
    * [jcc][t4][10120][10898][3.51.90] Invalid operation: result   *
    * set is closed. ERRORCODE=-4470, SQLSTATE=null                *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • The code was modified so that push notifications occur within
    transactions.
    
    The fix for this APAR is currently targeted for inclusion in
    release 6.0.0.0.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM90781

  • Reported component name

    WORKLIGHT ENTER

  • Reported component ID

    5725I4300

  • Reported release

    505

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-06-10

  • Closed date

    2013-07-18

  • Last modified date

    2013-07-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WORKLIGHT ENTER

  • Fixed component ID

    5725I4300

Applicable component levels

  • R505 PSY

       UP

  • R506 PSY

       UP



Document information

More support for: IBM Worklight

Software version: 505

Reference #: PM90781

Modified date: 2013-07-18