PM89317: UNABLE TO BUILD AND DEPLOY BLACKBERRY 10 ENVIRONMENT, WHEN DEVELOPING ON A MAC OR LINUX MACHINE

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • When attempting to build and deploy an application for a
    Blackberry 10 environment on a Mac or Linux machine, the build
    fails with an error saying:
    WLST1040E: blackberry10 build failed: Failed copying web
    resources to native project (blackberry10)
    

Local fix

  • Before each Worklight build, perform the following steps:
    1. In the native directory for the Blackberry 10 environment,
    change to the "/apps/<app
    name>/blackberry10/native/www/webresources/default/wlclient/js"
    directory.
    2. Set the permissions of the js directory to include ow write
    true (allow owner to write).
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Developers building applications for Blackberry on Mac or    *
    * Linux machines.                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * The permissions are not properly set for web resources in    *
    * the native Blackberry project.                               *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • The code has been modified to correct the permissions issue.
    
    The fix for this APAR is currently targeted for inclusion in
    fixpack 5.0.6.0.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM89317

  • Reported component name

    WORKLIGHT CONSU

  • Reported component ID

    5725I4301

  • Reported release

    505

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-05-18

  • Closed date

    2013-05-18

  • Last modified date

    2013-05-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WORKLIGHT CONSU

  • Fixed component ID

    5725I4301

Applicable component levels

  • R505 PSY

       UP



Rate this page:

(0 users)Average rating

Document information


More support for:

IBM Worklight

Software version:

5.0.5

Reference #:

PM89317

Modified date:

2013-05-18

Translate my page

Machine Translation

Content navigation