PM88753: CLIENTS MAY SEE AN ABENDS0C4 PIC10 IN AGGLSPC NEAR LABEL @DDST DUE TO INCORRECTLY SET ACCESS REGISTER.

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • After DB2 maintenance, clients may experience ABENDS0C4
    pic10 in AGGLSPC near label @DDST due to incorrectly set access
    register.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IBM HourGlass R610 users.                *
    ****************************************************************
    * PROBLEM DESCRIPTION: An ABENDS0C4 (pic 10 or 11) can occur   *
    *                      in the HourGlass AGGLSPC module near    *
    *                      offset +x'23F0' due to incorrectly set  *
    *                      access register.                        *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF.                               *
    ****************************************************************
    

Problem conclusion

  • ***************************************************************
    * FIX DESCRIPTION:     The logic in module AGGLSPC near offset*
    *                      x'23F0' has been modified to correctly *
    *                      set an access register prior to ref-   *
    *                      erencing it near that location.        *
    *                                                             *
    ***************************************************************
    * PRODUCT ELEMENTS AFFECTED BY THIS FIX:                      *
    ***************************************************************
    * NEW ELEMENTS ADDED:                                         *
    *     None.                                                   *
    *                                                             *
    ***************************************************************
    * EXISTING ELEMENTS MODIFIED:                                 *
    *   SAGGLOAD(AGGLSPC ) on behalf of module:                   *
    *            AGGLSPC .#000044.2013/05/09.17:14:31.PM88753     *
    *                                                             *
    ***************************************************************
    * EXISTING ELEMENTS DELETED:                                  *
    *     None.                                                   *
    *                                                             *
    ***************************************************************
    * IMPLEMENTATION:      To complete the implementation of this *
    *                      fix, please ensure that all new or     *
    *                      updated product elements are copied to *
    *                      their respective execution/working     *
    *                      libraries.                             *
    *                                                             *
    ***************************************************************
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM88753

  • Reported component name

    IBM HOURGLASS

  • Reported component ID

    5655U4200

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-05-09

  • Closed date

    2013-08-05

  • Last modified date

    2013-10-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK97354

Modules/Macros

  •    AGGLSPC
    

Fix information

  • Fixed component name

    IBM HOURGLASS

  • Fixed component ID

    5655U4200

Applicable component levels

  • R610 PSY UK97354

       UP13/09/10 P F309

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.



Rate this page:

(0 users)Average rating

Add comments

Document information


More support for:

HourGlass

Software version:

6.1

Reference #:

PM88753

Modified date:

2013-10-03

Translate my page

Machine Translation

Content navigation