PM88306: SubInterface name not being displayed on Application Component Interface in Rational System Architect

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Abstract:  SubInterface name not being displayed on Application
    Component Interface in IBM Rational System Architect even if the
    option SubInterfaces is enabled in Display Mode
    
    Error Description:
    
    1. Create a new App Component Interface Diagram
    2. Create 2 Application Component symbols
    3. Draw a Application Component Interface relation between them
    and also Define a SunInterface within it
    4. Once done enable option SubInterfaces in Display Mode for the
    relationship
    
    Notice that regardless of the option being enabled or disabled
    the name of SubInterface is not displayed. However a pointed
    symbol gets displayed
    
    Workaround:  Under Tools \ Preferences, check Verical Resize
    and/or Horizontal Resize
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Sub-Interface names and other displayable properties are
    sometimes truncated to the point of invisibility due to
    being assigned a zero-height text rectangle.
    

Problem conclusion

  • A prior fix to System Architect introduced an error into the
    function that determines when to allow a text rectangle to
    be resized and when to leave it as-is.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM88306

  • Reported component name

    TLOGIC SYS ARCH

  • Reported component ID

    5724V68SA

  • Reported release

    B41

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-05-02

  • Closed date

    2013-06-14

  • Last modified date

    2013-06-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC SYS ARCH

  • Fixed component ID

    5724V68SA

Applicable component levels

  • RB41 PSN

       UP



Rate this page:

(0 users)Average rating

Add comments

Document information


More support for:

Rational System Architect

Software version:

11.4.1

Reference #:

PM88306

Modified date:

2013-06-14

Translate my page

Machine Translation

Content navigation