Error description

  • If you start an interop server with the -lightServer switch, you
    will receive an error when you open modules in DOORS Web Access
    that says 'CACHE_NOT_INITIALISED'
    

Local fix

Problem summary

  • There is a GetDocument call that should be flagged as a
    HEAVYWEIGHT operation, and so get diverted away from the
    lightweight Interop, but which was incorrectly defaulting to the
     LIGHTWEIGHT value.  This meant that is was being received by
    the lightweight interop, which was not loading module data that
    the GetDocument call should have, and causing the error of an
    empty cache when the system was assuming it would have loaded
    the data.
    

Problem conclusion

  • The GetDocument call was corrected to use the HEAVYWEIGHT flag
    instead of defaulting to LIGHWEIGHT.
    

Temporary fix

  • Simplest workaround is to just not run using the lightweight
    option.
    

Comments

  • This happens in versions of DOORS prior to DOORS 9.5.1.2
    

APAR Information

  • APAR number

    PM86656

  • Reported component name

    TLOGIC DOORS WE

  • Reported component ID

    5724V97WA

  • Reported release

    950

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-04-09

  • Closed date

    2013-11-07

  • Last modified date

    2013-11-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS WE

  • Fixed component ID

    5724V97WA

Applicable component levels

  • R951 PSY

       UP