  • Client's may experience a S0C4 in AGGLSPC#39
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IBM HourGlass R610 users.                *
    ****************************************************************
    * PROBLEM DESCRIPTION: Intermittent s0C4 in AGGLSPC due to     *
    *                      incorrect base register to control      *
    *                      block RBWORK.                           *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF.                               *
    ****************************************************************
    

Problem conclusion

  • ***************************************************************
    * FIX DESCRIPTION:     Corrected the culprit base register.   *
    *                                                             *
    ***************************************************************
    * PRODUCT ELEMENTS AFFECTED BY THIS FIX:                      *
    ***************************************************************
    * NEW ELEMENTS ADDED:                                         *
    *     None.                                                   *
    *                                                             *
    ***************************************************************
    * EXISTING ELEMENTS MODIFIED:                                 *
    *   SAGGLOAD(AGGLSPC ).#000043.2013/04/04.19:25:47.PM85996    *
    *                                                             *
    ***************************************************************
    * EXISTING ELEMENTS DELETED:                                  *
    *     None.                                                   *
    *                                                             *
    ***************************************************************
    * IMPLEMENTATION:      After applying this PTF, all users     *
    *                      need to re-run the HourGlass           *
    *                      customization process and restart      *
    *                      the AGGLINK address space via the      *
    *                      AGGOFF and AGGON started tasks.        *
    *                                                             *
    *                      The parts replaced by this fix are     *
    *                      being modified by the HourGlass        *
    *                      customization process.                 *
    *                                                             *
    ***************************************************************
    

Temporary fix

Comments

  • This APAR has been seen to cause overlays to pages of storage,
    especially ESQA storage, whose address corresponds to the first
    word of a PSW.  For example, overlays have been observed to the
    page at 070C0000 in storage, the page at 078D1000 in storage,
    etc.  Since these storage addresses tend to be within above the
    line SQA where various critical system control blocks live, the
    symptoms of the overlay can be unpredictable, and the impact can
     be significant.  In the case of an overlay at one of these
    "PSW-like addresses", the overlay content typically has the hex
    byte value X'E8' at offset +X'31' into the page, and many zeros
    beginning at offset +X'54' into the page.
    

APAR Information

  • APAR number

    PM85996

  • Reported component name

    IBM HOURGLASS

  • Reported component ID

    5655U4200

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-04-01

  • Closed date

    2013-04-16

  • Last modified date

    2013-09-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • AGGLSPC
    

Fix information

  • Fixed component name

    IBM HOURGLASS

  • Fixed component ID

    5655U4200

Applicable component levels

  • R610 PSY UK93506

       UP13/04/18 P F304

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
30 April 2020