IBM Support

PM85292: RQM 401: ERROR for test cases without useful error message

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Environment:
    - Windows 7
     - Rational Quality Manager v 4.0.1 and Rational Functional
    Tester 8.3.0.1
    Reproducible Y/N: Y
    Description of problem:
    
    Error on UI and Warning in qm.log that states, 'the adapter is
    not available'
    
    Steps to reproduce:
    1. Create shared location for RFT scripts
    2. Import some RFT scripts (RFTScript1, RFTScript2, RFTScript3)
    from shared location
    3. Create test cases (TC1, TC2, TC3) and add RFT scripts
    (RFTScript1, RFTScript2, RFTScript3).
    4. Create test suite TSuite1 and add test cases TC1, TC2, TC3
    and set radio button for 'Run this suite in a sequence'.
    5. Create test suite execution record TSER1 for TSuite1.
    6. Connect RFT adapter to RQM.
    7. Create test cell TCell1 and add RFT adapter machine in it.
    8. Create execution schedule, set some execution date ? time,
    select test cell TCell1 and add TSER1.
    9. Select choose machines at run time.
    
    Actual Result:
    After executing the first step TC1 in a suite TSuite1, next
    steps are not getting executed. Following
    message is seen in the log - 'Execution could not be started due
    to unavailability of an execution adapter
    of type com.ibm.rqm.adapter.rft within test cell Test Cell 1 to
    run remote script RFTScript2'
    
    Step to reproduce:
    Workaround:
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Unable to execute next RFT script in a suite as part of
    execution schedule
    

Problem conclusion

  • Fixed in 4.0.3
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM85292

  • Reported component name

    RATL QUALITY MG

  • Reported component ID

    5724V1000

  • Reported release

    401

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-03-21

  • Closed date

    2013-06-10

  • Last modified date

    2013-06-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL QUALITY MG

  • Fixed component ID

    5724V1000

Applicable component levels

  • R401 PSN

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSR27Q","label":"Rational Quality Manager"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.0.1","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
10 June 2013