Skip to main content

PM83745: WITH HOURGLASS CUSTOMIZATION SETTING LEGACYDB2QUALIFICATION=Y, BYPASS CALL TO AGGELIG FOR CICS/DB2 TIME REQUESTS.


A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • For time requests originating from a CICS/DB2 application, with
    customization setting LEGACYDB2QUALIFICATION=Y, then it
    can be assumed that the intent of the user is that the DB2 time
    request should receive whatever altered date/time value is
    associated with the CICS region.  In this case, branching off to
    the AGGELIG routine is superfluous.  The logic in AGGLSPC will
    be altered so that CICS/DB2 time requests with
    LEGACYDB2QUALIFICATION=Y set, will bypass the call to AGGELIG,
    and proceed directly to retrieving the HourGlass-altered
    date/time value from the HourGlass CICS support.
    

Local fix

  • None available.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IBM HourGlass R610 users utilizing       *
    *                 HourGlass in the DB2 environment.            *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1. For DB2 time requests with the       *
    *                      LEGACYDB2QUALIFICATION=Y customization  *
    *                      setting, in certain cases, the          *
    *                      HourGlass Active Control Element Set    *
    *                      (ACES) data area was being scanned      *
    *                      unnecessarily, causing unnecessary      *
    *                      system overhead.                        *
    *                      2. There is a typographical error in    *
    *                      message AGGST03S, in HourGlass module   *
    *                      AGGLSSTC.                               *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF.                               *
    ****************************************************************
    

Problem conclusion

  • ***************************************************************
    * FIX DESCRIPTION:     1.  Make modifications in HourGlass    *
    *                      modules AGGELIG and AGGLSPC such that  *
    *                      DB2 time requests, with the            *
    *                      LEGACYDB2QUALIFICATION=Y customization *
    *                      setting, do not scan the HourGlass     *
    *                      Active Control Element Set(ACES) data  *
    *                      area.                                  *
    *                      2.  Correct the typographical error in *
    *                      message AGGST03S, in HoourGlass module *
    *                      AGGLSSTC.                              *
    *                                                             *
    ***************************************************************
    * PRODUCT ELEMENTS AFFECTED BY THIS FIX:                      *
    ***************************************************************
    * NEW ELEMENTS ADDED:                                         *
    *   None.                                                     *
    *                                                             *
    ***************************************************************
    * EXISTING ELEMENTS MODIFIED:                                 *
    *   SAGGLOAD(AGGFRONT) on behalf of CSECT:                    *
    *           (AGGELIG ) #000048.2013/03/25.12:40:23.PM83475    *
    *   SAGGLOAD(AGGLSPC ) #000042.2013/03/14.21:25:47.PM83745    *
    *   SAGGLOAD(AGGLSSTC) #000012.2013/02/27.17:05:53.PM83745    *
    *                                                             *
    ***************************************************************
    * EXISTING ELEMENTS DELETED:                                  *
    *   None.                                                     *
    *                                                             *
    ***************************************************************
    * IMPLEMENTATION:      1.  Copy the new/updated modules to the*
    *                      the HourGlass execution libraries, if  *
    *                      other than the SMP/E target libraries. *
    *                      2.  Since one or more of the load      *
    *                      modules replaced by this fix are up-   *
    *                      dated by the HourGlass customization   *
    *                      process, it will be necessary to reexe-*
    *                      cute the HourGlass customization pro-  *
    *                      cedure, which is distributed as        *
    *                      SAGGSAMP(AGGCUSTM).                    *
    *                      3.  Stop and restart HourGlass via the *
    *                      AGGOFF/AGGON operator command sequence.*
    *                                                             *
    ***************************************************************
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM83745

  • Reported component name

    IBM HOURGLASS

  • Reported component ID

    5655U4200

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-02-27

  • Closed date

    2013-03-27

  • Last modified date

    2013-05-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    AGGFRONT AGGLSPC  AGGLSSTC
    

Fix information

  • Fixed component name

    IBM HOURGLASS

  • Fixed component ID

    5655U4200

Applicable component levels

  • R610 PSY UK93219

       UP13/04/10 P F304

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

Rate this page:

(0 users)Average rating

Copyright and trademark information

IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.

Rate this page:


(0 users)Average rating

Add comments

Document information

HourGlass


Software version:
6.1


Reference #:
PM83745


Modified date:
2013-05-03

Translate my page

Content navigation