IBM Support

PM83634: CONNECT:EXPRESS 4.3.0 L1B2P040 ABEND S0C4 WILL BE FIXED IN 423, 430

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Issue comes from subsystem interface when a SSI request is
    inserted in monitor Queue and is not taken into account before
    timeout occurs on client side.
    When a timeout occurs, a detach on local SSI interface will
    remove the chain from client to cross memory interface and also
    remove all acquired areas. RCB is no longer available when
    monitor works with this request and an abend occurs.
    
    Because timeout occured on client side, this request should be
    ignored.
    
    Code will be fixed to check if RCB area is valid before any
    other action.
    

Local fix

  • STRRTC - 352109
    CN/CN
    Circumvention: None
    

Problem summary

  • ABEND 0C4 in module L1B2P040 offset 00000908
    A timeout occurs in subsystem interface and server does not
    manage it
    

Problem conclusion

  • Control on timeout is added on server side to control
    availability of data areas before working with incoming request
    in server queue
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM83634

  • Reported component name

    STR CON EXP Z/O

  • Reported component ID

    5655ST300

  • Reported release

    430

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-02-26

  • Closed date

    2013-03-07

  • Last modified date

    2013-03-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • L1B2P040
    

Fix information

  • Fixed component name

    STR CON EXP Z/O

  • Fixed component ID

    5655ST300

Applicable component levels

[{"Line of Business":{"code":"LOB59","label":"Sustainability Software"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS4PY2","label":"IBM Sterling Connect:Express"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.3"}]

Document Information

Modified date:
27 February 2021