PM83416: RIT WITH IBM MQ MULTIPLE SUBSCRIBE CORRELATION ID NOT RETURNING FROM SUBSCRIBE ACTION

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • RIT with IBM MQ multiple subscribe correlation ID not returning
    from subscribe action
    
    Steps to reproduce:
    
    1. Create the following RIT tests that use a single queue:
      Test 1 : Publish to IBM MQ message with correlation ID 1 ,
    publish to IBM MQ message with correlation ID 2
      Test 2 : Subscribe to IBM MQ message with correlation ID 1
      Test 3 : Subscribe to IBM MQ message with correlation ID 2
      Test 4 : Subscribe to IBM MQ message with correlation ID 1 ,
    Subscribe to IBM MQ message with correlation ID 2
    
    2. Clear queue manually and run Test 1, Test 2, Test 3 - all is
    well both messages received.
    3. Clear queue manually and run Test 1, Test 4
    
    Expected results:
    Upon performing step 3, Test 4 completes successfully
    
    Actual Results:
    Upon performing step 3, Test 4 does not return (although
    messages are removed from queue)
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users of Rational Integration Tester working with        *
    * WebSphere MQ                                                 *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * RIT with IBM MQ multiple subscribe correlation ID not        *
    * returning                                                    *
    * from subscribe action                                        *
    *                                                              *
    * Steps to reproduce:                                          *
    *                                                              *
    * 1. Create the following RIT tests that use a single queue:   *
    *   Test 1 : Publish to IBM MQ message with correlation ID 1 , *
    * publish to IBM MQ message with correlation ID 2              *
    *   Test 2 : Subscribe to IBM MQ message with correlation ID 1 *
    *   Test 3 : Subscribe to IBM MQ message with correlation ID 2 *
    *   Test 4 : Subscribe to IBM MQ message with correlation ID 1 *
    * ,                                                            *
    * Subscribe to IBM MQ message with correlation ID 2            *
    *                                                              *
    * 2. Clear queue manually and run Test 1, Test 2, Test 3 - all *
    * is                                                           *
    * well both messages received.                                 *
    * 3. Clear queue manually and run Test 1, Test 4               *
    *                                                              *
    * Expected results:                                            *
    * Upon performing step 3, Test 4 completes successfully        *
    *                                                              *
    * Actual Results:                                              *
    * Upon performing step 3, Test 4 does not return (although     *
    * messages are removed from queue)                             *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Upgrade to Rational Integration Tester v8.0.1.3 which        *
    * includes a fix for this issue                                *
    ****************************************************************
    

Problem conclusion

  • A fix for this issue was provided in version 8.0.1.3 of Rational
    Integration Tester
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM83416

  • Reported component name

    RATL INTEGRA TE

  • Reported component ID

    5725G79IT

  • Reported release

    801

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-02-22

  • Closed date

    2013-06-27

  • Last modified date

    2013-06-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL INTEGRA TE

  • Fixed component ID

    5725G79IT

Applicable component levels

  • R800 PSN

       UP

  • R801 PSY

       UP

  • R850 PSY

       UP



Document information


More support for:

Rational Test Workbench

Software version:

8.0.1

Reference #:

PM83416

Modified date:

2013-06-27