A fix is available
APAR status
Closed as program error.
Error description
This error can occur during qualification processing in the AGGELIG module, while processing elements stored in the Active Control Element Set (ACES) data area. An ABENDS0C4 can occur in AGGELIG near offset x'17FA' if an HourGlass dynamic refresh occurs while a qualification process involving multiple qualification phases is underway. A situation can arise in which one or more initial qualification phases process using one ACES data area, then a dynamic refresh occurs, meanwhile subsequent qualification phases attempt to use the new ACES data area with pointers obtained from the previous ACES data area, resulting in a possible ABENDS0C4.
Local fix
None available.
Problem summary
**************************************************************** * USERS AFFECTED: All IBM HourGlass R610 users utilizing * * HourGlass Control Elements and the * * HourGlass Repository to set and re- * * trieve altered date/time values for * * applications. * **************************************************************** * PROBLEM DESCRIPTION: This error can occur during the time * * request qualification processing in the * * AGGELIG module, while processing ele- * * ments stored in the Active Control * * Element Set (ACES) data area. An * * ABENDS0C4 can occur in AGGELIG near * * offset x'17FA' if an HourGlass dynamic * * refresh is processed while a time re- * * quest qualification process, involving * * multiple qualification phases, is * * underway. A situation can arise in * * which one or more of the initial quali- * * fication phases process using the ACES * * data area, meanwhile a dynamic refresh * * occurs, with the result that subsequent * * qualification phases attempt to * * reference the new ACES data area using * * pointers that were applicable to the * * previous ACES data area, and now no * * longer valid, resulting in a possible * * ABENDS0C4 as described above. * **************************************************************** * RECOMMENDATION: Apply the PTF. * ****************************************************************
Problem conclusion
*************************************************************** * FIX DESCRIPTION: Modify logic in the AGGLSPC program * * such that for all time requests that * * are qualified by an HourGlass Control * * Element, the pointer to the current * * Active Control Element Set (ACES) data * * area is consistent throughout the * * entire qualification process for each * * time request. * * * *************************************************************** * PRODUCT ELEMENTS AFFECTED BY THIS FIX: * *************************************************************** * NEW ELEMENTS ADDED: * * None. * * * * NEW ELEMENTS ADDED: * * None. * *************************************************************** * EXISTING ELEMENTS MODIFIED: * * SAGGLOAD(AGGFRONT) on behalf of CSECT: * * (AGGELIG ) #000045.2013/02/26.17:18:15.PM83340 * * * *************************************************************** * EXISTING ELEMENTS DELETED: * * None. * *************************************************************** * IMPLEMENTATION: 1. Copy the new/updated modules to the* * the HourGlass execution libraries, if * * other than the SMP/E target libraries. * * 2. Since one or more of the load * * modules replaced by this fix are up- * * dated by the HourGlass customization * * process, it will be necessary to reexe-* * cute the HourGlass customization pro- * * cedure, which is distributed as * * SAGGSAMP(AGGCUSTM). * * 3. Stop and restart HourGlass via the * * AGGOFF/AGGON operator command sequence.* * * ***************************************************************
Temporary fix
Comments
APAR Information
APAR number
PM83340
Reported component name
IBM HOURGLASS
Reported component ID
5655U4200
Reported release
610
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-02-21
Closed date
2013-03-27
Last modified date
2013-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK92980
Modules/Macros
AGGFRONT
Fix information
Fixed component name
IBM HOURGLASS
Fixed component ID
5655U4200
Applicable component levels
R610 PSY UK92980
UP13/03/29 P F303
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.