IBM Support

PM83340: IF A DYNAMIC REFRESH OCCURS DURING A QUALIFICATION PROCESS, MULTIPLE ACES AREAS MAY BE ACCESSED CAUSING POSSIBLE ABENDS0C4.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • This error can occur during qualification processing in the
    AGGELIG module, while processing elements stored in the
    Active Control Element Set (ACES) data area.
    An ABENDS0C4 can occur in AGGELIG near offset x'17FA' if an
    HourGlass dynamic refresh occurs while a qualification process
    involving multiple qualification phases is underway.  A
    situation can arise in which one or more initial qualification
    phases process using one ACES data area, then a dynamic refresh
    occurs, meanwhile subsequent qualification phases attempt to use
    the new ACES data area with pointers obtained from the previous
    ACES data area, resulting in a possible ABENDS0C4.
    

Local fix

  • None available.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IBM HourGlass R610 users utilizing       *
    *                 HourGlass Control Elements and the           *
    *                 HourGlass Repository to set and re-          *
    *                 trieve altered date/time values for          *
    *                 applications.                                *
    ****************************************************************
    * PROBLEM DESCRIPTION: This error can occur during the time    *
    *                      request qualification processing in the *
    *                      AGGELIG module, while processing ele-   *
    *                      ments stored in the Active Control      *
    *                      Element Set (ACES) data area.  An       *
    *                      ABENDS0C4 can occur in AGGELIG near     *
    *                      offset x'17FA' if an HourGlass dynamic  *
    *                      refresh is processed while a time re-   *
    *                      quest qualification process, involving  *
    *                      multiple qualification phases, is       *
    *                      underway.  A situation can arise in     *
    *                      which one or more of the initial quali- *
    *                      fication phases process using the ACES  *
    *                      data area, meanwhile a dynamic refresh  *
    *                      occurs, with the result that subsequent *
    *                      qualification phases attempt to         *
    *                      reference the new ACES data area using  *
    *                      pointers that were applicable to the    *
    *                      previous ACES data area, and now no     *
    *                      longer valid, resulting in a possible   *
    *                      ABENDS0C4 as described above.           *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF.                               *
    ****************************************************************
    

Problem conclusion

  • ***************************************************************
    * FIX DESCRIPTION:     Modify logic in the AGGLSPC program    *
    *                      such that for all time requests that   *
    *                      are qualified by an HourGlass Control  *
    *                      Element, the pointer to the current    *
    *                      Active Control Element Set (ACES) data *
    *                      area is consistent throughout the      *
    *                      entire qualification process for each  *
    *                      time request.                          *
    *                                                             *
    ***************************************************************
    * PRODUCT ELEMENTS AFFECTED BY THIS FIX:                      *
    ***************************************************************
    * NEW ELEMENTS ADDED:                                         *
    *   None.                                                     *
    *                                                             *
    * NEW ELEMENTS ADDED:                                         *
    *   None.                                                     *
    ***************************************************************
    * EXISTING ELEMENTS MODIFIED:                                 *
    *   SAGGLOAD(AGGFRONT) on behalf of CSECT:                    *
    *           (AGGELIG ) #000045.2013/02/26.17:18:15.PM83340    *
    *                                                             *
    ***************************************************************
    * EXISTING ELEMENTS DELETED:                                  *
    *   None.                                                     *
    ***************************************************************
    * IMPLEMENTATION:      1.  Copy the new/updated modules to the*
    *                      the HourGlass execution libraries, if  *
    *                      other than the SMP/E target libraries. *
    *                      2.  Since one or more of the load      *
    *                      modules replaced by this fix are up-   *
    *                      dated by the HourGlass customization   *
    *                      process, it will be necessary to reexe-*
    *                      cute the HourGlass customization pro-  *
    *                      cedure, which is distributed as        *
    *                      SAGGSAMP(AGGCUSTM).                    *
    *                      3.  Stop and restart HourGlass via the *
    *                      AGGOFF/AGGON operator command sequence.*
    *                                                             *
    ***************************************************************
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM83340

  • Reported component name

    IBM HOURGLASS

  • Reported component ID

    5655U4200

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-02-21

  • Closed date

    2013-03-27

  • Last modified date

    2013-04-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK92980

Modules/Macros

  • AGGFRONT
    

Fix information

  • Fixed component name

    IBM HOURGLASS

  • Fixed component ID

    5655U4200

Applicable component levels

  • R610 PSY UK92980

       UP13/03/29 P F303

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
30 April 2020