PM82854: CINB ABENDAICA CIUCINB2

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • CINB transaction may abend AICA.  EXEC CICS SUSPEND logic needs
    to be enabled within the SAVE_AFF_TABLE and SAVE_AFF_TABLE
    routines.
    
    Additional Symptom(s) Search Keyword(s): KIXREVWJB
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS IA Version 3.2 users.               *
    ****************************************************************
    * PROBLEM DESCRIPTION: EXEC CICS SUSPEND commands intended to  *
    *                      prevent AICA Abend in CIUCINB2 module   *
    *                      are not issued.                         *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF and perform HOLD ACTION.       *
    ****************************************************************
    Program block controlling the issuing of the SUSPEND commands
    is executed only once within the procedures SAVE_DEP_TABLE and
    SAVE_AFF_TABLE. It does not enable the SUSPEND commands
    to be issued.
    

Problem conclusion

  • Program logic was corrected to provide the issuing of the
    SUSPEND commands to avoid the AICA Abend.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM82854

  • Reported component name

    CICS INTER ANAL

  • Reported component ID

    5655U8600

  • Reported release

    320

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-02-14

  • Closed date

    2013-04-03

  • Last modified date

    2013-05-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK93296 PM86830

Modules/Macros

  •    CIUCINB2
    

Fix information

  • Fixed component name

    CICS INTER ANAL

  • Fixed component ID

    5655U8600

Applicable component levels

  • R320 PSY UK93296

       UP13/04/24 P F304

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.



Rate this page:

(0 users)Average rating

Add comments

Document information


More support for:

CICS Interdependency Analyzer for z/OS

Software version:

3.2

Reference #:

PM82854

Modified date:

2013-05-06

Translate my page

Machine Translation