APAR status
Closed as program error.
Error description
Error Description IBM Sterling Connect:Express for z/OS V4.3.0.4 B2PRQ23E ERROR ON SYSIN when using P1B2PRQ2 and 2 send commands including one of these parameters RDS, DTP, FST, TMD, STU, WTI, WTR
Local fix
STRRTC 364703 MM/MM Circumvention: None
Problem summary
Keyword redundancy code for some keywords are missing. If a P1B2PRQ2 JOB submit more than one request in the same SYSIN, the second one may be rejected. Keywords in error are RDS, DTP, FST, TMD, STU, WTI, WTR
Problem conclusion
Keyword redundancy code added for missing keywords
Temporary fix
Comments
APAR Information
APAR number
PM81504
Reported component name
STR CON EXP Z/O
Reported component ID
5655ST300
Reported release
430
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-01-28
Closed date
2013-01-28
Last modified date
2013-01-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
P1B2PRQ2
Fix information
Fixed component name
STR CON EXP Z/O
Fixed component ID
5655ST300
Applicable component levels
R430 PSY
UP
Rate this page:
Average rating
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.