APAR status
Closed as program error.
Error description
ABND=0C4-0000003B - LOC=DSNWAAP0.DSNWALCK+258C If the length of the caller's return area is exactly the same as the length of the response area, DSNWALCK will incorrectly assume that it don't fit. This will cause the ABEND0C4.
Local fix
n/a
Problem summary
**************************************************************** * USERS AFFECTED: All users of DB2 for z/OS 9 and 10. * **************************************************************** * PROBLEM DESCRIPTION: 1. An IFI READS request causes ABEND0C4 * * in CSECT DSNWALCK. * * * * 2. An invalid FROM CCSID may be used * * when IFCID217 is written. * **************************************************************** * RECOMMENDATION: * **************************************************************** 1. If the size of the response area used for an IFI request is exactly the size of the return data, an incorrect pointer will be used by DB2 IFI code to update IFCA fields. This will lead to an ABEND0C4 in CSECT DSNWALCK. 2. When writing an IFCID217, DB2 may incorrectly determine the FROM CCSID to be used to convert the QW0217QA field to UTF. Dealing with an invalid CCSID, will cause a significant number of CPU cycles to be used by the conversion services. This can lead to an increase of CPU cycles in the conversion services code.
Problem conclusion
1. Correct the logic error for updating IFCA fields when the response data equals the return area size. 2. Correctly determine the FROM CCSID when writing IFCID217
Temporary fix
Comments
APAR Information
APAR number
PM80948
Reported component name
DB2 OS/390 & Z/
Reported component ID
5740XYR00
Reported release
A10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-01-19
Closed date
2013-05-07
Last modified date
2013-05-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK94119 UK94120
Modules/Macros
DSNTXSTB DSNWALCK
Fix information
Fixed component name
DB2 OS/390 & Z/
Fixed component ID
5740XYR00
Applicable component levels
RA10 PSY
UP
R910 PSY
UP
Rate this page:
Average rating
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.