PM80910: Merge from Version Tree Browser to UCM branch uses incorrect Activity

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • If you do a merge in the IBM Rational ClearCase Version Tree
    Browser from a UCM Development view, you will find that the
    checkout on the UCM Integration stream will use the activity
    that is currently set in the Development view.
    
    Steps to reproduce:
    ? Have a version on the Development stream and deliver its
    activity to the Integration stream.
    ? Draw a baseline on the Integration stream.
    ? Create a new version on the Development stream using the
    Development view.
    ? Open the version tree of the element from the Development view
    and merge the newly created version on the Development stream
    with the LATEST version on the Integration stream. The
    Integration stream branch is checkedout to the current view
    using the currently set activity.
    
    Workaround:
    Use a view set to the target stream for merges that are
    initiated from the version tree.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Merge from Version Tree Browser to UCM branch allowed with an
    incorrect Activity
    

Problem conclusion

  • A fix is available in ClearCase version 8.0.0.7
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM80910

  • Reported component name

    CLEARCASE WIN

  • Reported component ID

    5724G2900

  • Reported release

    711

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-01-18

  • Closed date

    2013-07-01

  • Last modified date

    2013-09-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CLEARCASE WIN

  • Fixed component ID

    5724G2900

Applicable component levels

  • R800 PSY

       UP