A fix is available
APAR status
Closed as program error.
Error description
You use the WUI or other API program (such as the CICS Explorer) to install a SYSLINK definition. On the install request, you use the STATE CHECK (STATECHK) set to YES option. CPSM finds no errors, but does not continue with the install of the resource (as it would with other types of resource installs.) . There are also instances where a STATECHK fails when it should not, or returns OK when it really should fail. . Additional Keywords/Symptoms: EYUVC1230I KIXREVSVR
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICSPlex SM V5R1M0 Users * **************************************************************** * PROBLEM DESCRIPTION: Various errors may occur when using the * * state check option (STATECHK) when * * performing a dynamic install of * * SYSLINKs. * * * * - A state failure may be reported * * when none exists. * * * * - A state failure may not be reported * * when one exists. * * * * - If no state failures are detected, * * the install is not performed. * **************************************************************** * RECOMMENDATION: After applying the PTF that resolves this * * APAR, all CMASes and MASes must be * * restarted. Note that the restarts do not * * need to occur at the same time. * **************************************************************** When the state check option is used for a dynamic SYSLINK install, method EYU0TALI (TALI) in the MP CMAS builds a list of all definitions to be installed, and passes this to the apropriate MASes, indicating that the definitions should only be state checked. This drives method EYU0BNSC (BNSC) in the MASes, which checks if the definitions that are to be installed are already installed in the MAS. If they are, and their state is not consistent with them being re-installed, then BNSC returns a state error to TALI, which reports the errors and terminates the install process. If the definitions are not installed, or are in a state that allows them to be re-installed, then BNSC returns an OK status to TALI, which then should resend the definitions to the MASes with an indication that they should be installed. Part of the information passed to BNSC by TALI, along with logic errors in BNSC, can result in BNSC performing SYSLINK state check processing incorrectly. A logic error in TALI results it it not driving the install process if BNSC returns an OK response for a state check.
Problem conclusion
BNSC has been updated to correct the logic errors that can cause it to perform SYSLINK state check processing incorrectly. TALI has been updated to pass the proper information to BNSC so that it can perform SYSLINK state check processing correctly. TALI has also been updated to properly drive the install process when BNSC returns an OK status for state check processing.
Temporary fix
FIX AVAILABLE BY PTF ONLY
Comments
APAR Information
APAR number
PM80464
Reported component name
CICS TS Z/OS V5
Reported component ID
5655Y0400
Reported release
80M
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-01-11
Closed date
2013-01-23
Last modified date
2015-03-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK91138
Modules/Macros
EYU0BNSC EYU0TALI EYUA2616 EYUC2616 EYUE2616 EYUL2616 EYUP2616 EYUT2616 EYUY2616
SC34289100 |
Fix information
Fixed component name
CICS TS Z/OS V5
Fixed component ID
5655Y0400
Applicable component levels
R80M PSY UK91138
UP13/01/25 P F301
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
04 March 2015