PM80419: CPSM SYSLINK INSTALL WITH STATECHK = YES MAY REPORT INSTALL SUCCESSFUL WITH NOTHING BEING INSTALLED

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • You use the WUI or other API program (such as the CICS Explorer)
    to install a SYSLINK definition. On the install request, you use
    the STATE CHECK (STATECHK) set to YES option. CPSM finds no
    errors, but does not continue with the install of the resource
    (as it would with other types of resource installs.)
    .
    There are also instances where a STATECHK fails when it should
    not, or returns OK when it really should fail.
    .
    Additional Keywords/Symptoms:
    EYUVC1230I KIXREVSVR
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICSPlex SM V4R1M0 and V4R2M0 Users      *
    ****************************************************************
    * PROBLEM DESCRIPTION: Various errors may occur when using the *
    *                      state check option (STATECHK) when      *
    *                      performing a dynamic install of         *
    *                      SYSLINKs.                               *
    *                                                              *
    *                      -  A state failure may be reported      *
    *                         when none exists.                    *
    *                                                              *
    *                      -  A state failure may not be reported  *
    *                         when one exists.                     *
    *                                                              *
    *                      -  If no state failures are detected,   *
    *                         the install is not performed.        *
    ****************************************************************
    * RECOMMENDATION: After applying the PTF that resolves this    *
    *                 APAR, all CMASes and MASes must be           *
    *                 restarted.  Note that the restarts do not    *
    *                 need to occur at the same time.              *
    ****************************************************************
    When the state check option is used for a dynamic SYSLINK
    install, method EYU0TALI (TALI) in the MP CMAS builds a list of
    all definitions to be installed, and passes this to the
    apropriate MASes, indicating that the definitions should only be
    state checked.  This drives method EYU0BNSC (BNSC) in the MASes,
    which checks if the definitions that are to be installed are
    already installed in the MAS.  If they are, and their state is
    not consistent with them being re-installed, then BNSC returns a
    state error to TALI, which reports the errors and terminates the
    install process.  If the definitions are not installed, or are
    in a state that allows them to be re-installed, then BNSC
    returns an OK status to TALI, which then should resend the
    definitions to the MASes with an indication that they should be
    installed.
    
    Part of the information passed to BNSC by TALI, along with logic
    errors in BNSC, can result in BNSC performing SYSLINK state
    check processing incorrectly.
    
    A logic error in TALI results it it not driving the install
    process if BNSC returns an OK response for a state check.
    

Problem conclusion

  • BNSC has been updated to correct the logic errors that can cause
    it to perform SYSLINK state check processing incorrectly.
    
    TALI has been updated to pass the proper information to BNSC so
    that it can perform SYSLINK state check processing correctly.
    TALI has also been updated to properly drive the install process
    when BNSC returns an OK status for state check processing.
    

Temporary fix

  • FIX AVAILABLE BY PTF ONLY
    

Comments

APAR Information

  • APAR number

    PM80419

  • Reported component name

    CICS TS Z/OS V4

  • Reported component ID

    5655S9700

  • Reported release

    60M

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-01-11

  • Closed date

    2013-01-23

  • Last modified date

    2013-02-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PM80464 UK91136 UK91137

Modules/Macros

  •    EYUA2616 EYUC2616 EYUE2616 EYUL2616 EYUP2616
    EYUT2616 EYUY2616 EYU0BNSC EYU0TALI
    

Publications Referenced
SC34703200SC34720400   

Fix information

  • Fixed component name

    CICS TS Z/OS V4

  • Fixed component ID

    5655S9700

Applicable component levels

  • R60M PSY UK91136

       UP13/01/25 P F301

  • R70M PSY UK91137

       UP13/01/25 P F301

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: