PM79949: NAVIGATOR CONFIGURED WITH A PORTAL PAGE AS THE START AREA FAILS TO RENDER ANONYMOUSLY

 

APAR status

  • Closed as program error.

Error description

  • Navigator component fails to render anonymously when:
    - the start area is configured to use a portal page (from the
    Portal Site library)
    - and the result design field is set to obtain either the
    title and/or the name of the resulting portal pages items (eg:
    using a placeholder tag)
    
    The following errors may be seen when tracing is enabled:
    Exception: java.lang.IllegalArgumentException:
    Using global scope (no user) and ISOLATED isolation mode - not
    allowed. Will continue rendering.
    

Local fix

  • None available
    

Problem summary

  • Navigator component fails to render anonymously when:
    - the start area is configured to use a portal page (from the
    Portal Site library)
    - and the result design field is set to obtain either the title
    and/or the name of the resulting portal pages items (eg:
    using a placeholder tag)
    
    The following errors may be seen when tracing is enabled:
    Exception: java.lang.IllegalArgumentException:
    Using global scope (no user) and ISOLATED isolation mode - not
    allowed. Will continue rendering.
    

Problem conclusion

  • The code was updated to allow the navigator component to resolve
    successfully given an anonymous user context with a portal page
    item configuraed as the start area.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM79949

  • Reported component name

    LOTUS WEB CONT

  • Reported component ID

    5724I2900

  • Reported release

    800

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-01-03

  • Closed date

    2013-01-14

  • Last modified date

    2013-01-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    LOTUS WEB CONT

  • Fixed component ID

    5724I2900

Applicable component levels

  • R800 PSY

       UP