Skip to main content

PM79749: Simulator in Rational Statemate does not release memory


Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • when viewing memory usage in Windows Task Manager, you see that
    Rational Statemate is consuming a lot of memory
    
    CAUSE:
    When running simulation in GUI mode and restarting or rebuilding
    simulation then it does not free the allocated memory of the
    previous session.
    
    STEPS TO REPRODUCE:
    - Closing and restarting simulation without closing the profile
    does not release memory.
    OR
    - In big models and long simulation runs you quickly reach an
    out of memory.
    
    WORKAROUND
    To work around the problem you must close the Simulation module
    completely and re-launch it.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Statemate Simulator does not release memory
    

Problem conclusion

  • Fixed in 4.6.1.7
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM79749

  • Reported component name

    TLOGIC STATEMAT

  • Reported component ID

    5724V76SM

  • Reported release

    461

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-12-27

  • Closed date

    2013-04-04

  • Last modified date

    2013-04-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC STATEMAT

  • Fixed component ID

    5724V76SM

Applicable component levels

  • R461 PSN

       UP

Rate this page:

(0 users)Average rating

Copyright and trademark information

IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.

Rate this page:


(0 users)Average rating

Add comments

Document information

Rational Statemate


Software version:
4.6.1


Reference #:
PM79749


Modified date:
2013-04-04

Translate my page

Content navigation