IBM Support

PM79566: Post-migration, Portal does not start properly due to an invalid ctx root. More than one attempt to change ctx root will fail.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • After the Post migration task has completed, or when changing th
    

Local fix

  • This issue can be worked around by modifying the <WPS_Install_Lo
    

Problem summary

  • After the Post migration task has completed, or when changing
    the Portal context root a second time, errors can occur on
    Portal start. This is due to a hard coded context root for
    webdav (wps).  Since this hard coded value is present, you can
    not successfully modify the context root of Portal after a
    migration or migrate successfully after a successful context
    root change.  This APAR resolves this behavior.
    

Problem conclusion

  • Fix available in CCF05
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM79566

  • Reported component name

    WEBSPHERE PORTA

  • Reported component ID

    5724E7600

  • Reported release

    800

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-12-20

  • Closed date

    2013-04-17

  • Last modified date

    2013-04-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WEBSPHERE PORTA

  • Fixed component ID

    5724E7600

Applicable component levels

  • R800 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSHRKX","label":"WebSphere Portal"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0","Line of Business":{"code":"LOB31","label":"WCE Watson Marketing and Commerce"}}]

Document Information

Modified date:
21 December 2021