PM78960: DB_VISTA 3 (ERRNO == 'INAPPROPRIATE IOCTL FOR DEVICE') ON MULTITOOL SYNCREPLICA -IMPORT IN PERMISSION PRESERVING REPLICA


Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • This defect affects IBM Rational ClearCase MultiSite sync import
    operations which may, on occasion, result in the following
    errors during import of a synchronization packet:
    
    2012-09-05T10:25:36+03:00 db_server(9048): Error: db_VISTA error
    3
    
    2012-08-31T08:57:08+03:00 db_server(30512): Error: db_VISTA
    error 3 (errno == 'Inappropriate ioctl for device')
    
    2012-08-17T16:06:25+02:00 db_server(25948): Error: DBMS error in
     '/vobs/atria/lib/db/db__oplog.c' line 122
    
    
    This has been observed when the importing replica attempts to
    process the same oplog twice. The second operation fails with
    db_VISTA 3 error indicating it is a duplicate oplog. The problem
    has only been seen on protect oplogs and does not appear to
    cause any problems with synchronization.
    
    Steps to reproduce: The exact conditions to reproduce this issue
    are unknown.
    
    Workaround: There is no known workaround. However, the issue
    does not present a risk to VOB database integrity and does not
    prevent synchronization so no workaround is necessary.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    IBM Rational ClearCase MultiSite sync import operations may
    result in 'db_VISTA error 3'
    

Problem conclusion

  • The exact conditions to reproduce this issue are unknown.
    
    Workaround: The issue does not present a risk to VOB database in
    tegrity and does not prevent synchronization so no workaround is
     necessary.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM78960

  • Reported component name

    CC&CC MSITE UNI

  • Reported component ID

    5724G3301

  • Reported release

    712

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-12-11

  • Closed date

    2012-12-19

  • Last modified date

    2012-12-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

Rate this page:

(0 users)Average rating

Copyright and trademark information

IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.

Rate this page:


(0 users)Average rating

Add comments

Document information

Rational ClearCase MultiSite


Software version:
7.1.2


Reference #:
PM78960


Modified date:
2012-12-19

Translate my page

Content navigation