A fix is available
APAR status
Closed as program error.
Error description
When stored procedures are called while using the Classic CLI/ODBC driver, the return values of output or input/output parameters may get truncated. This will particularly be an issue when using InfoSphere DataStage z/OS File Stage because it uses the Classic system stored procedure and the Classic CLI/ODBC driver underneath. . Additionally when binding host variables and passing zero length strings, the Classic CLI/ODBC currently returns a 'feature not implemented' error.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Classic Federation * **************************************************************** * PROBLEM DESCRIPTION: The return values of output or * * input/output parameters of a Classic * * system stored procedure may be * * truncated unexpectedly. * * This problem was reported when * * InfoSphere DataStage z/OS File Stage * * was used to access the Classic * * CLI/ODBC driver to call a Classic * * system stored procedure. * * When a CREATE TABLE was processed, the * * stored procedue returned a truncated * * DD name, confirmed by the following * * trace entry in the server log: * * 2012-12-05-11.48.46.186950 RC(03), * * SpcRC(ffffffff), * * Data(00000000,00000000) Node(220), * * Task(9136984) QP, func , line 654 in * * CAC.V101.RUP3.B120507.C(AAQCQPIN) * * 'CREATE TABLE * * SYSDST.DSTTBL123456789101 DBTYPE * * SEQUENTIAL DD "SYS0"' ' (RAWDATA * * SOURCE DEFINITION DATAMAP OFFSET 0 * * LENGTH 35 DATATYPE C ' 'USE AS * * VARCHAR(35)) ' * * . * * Where the DD above should have been * * an 8-char DD name. * **************************************************************** * RECOMMENDATION: * **************************************************************** See problem description.
Problem conclusion
Code has been updated to address the truncation issue. A change has also been introduced to allow zero-length strings to be passed when binding host variables. To obtain the complete fix, in addition to the PTF, please download the most current Classic ODBC/CLI driver.
Temporary fix
Comments
APAR Information
APAR number
PM78907
Reported component name
CLASSIC FED & E
Reported component ID
5697I8200
Reported release
A10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-12-10
Closed date
2012-12-14
Last modified date
2013-01-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
CECCCHDL CECCENDE CECCENGN CECCFAHD CECCGET CECCHNDL CECCPUT CECCSQER CECCSQL CECOCONV
Fix information
Fixed component name
CLASSIC FED & E
Fixed component ID
5697I8200
Applicable component levels
RA10 PSY UK90370
UP12/12/19 P F212
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
Rate this page:
Average rating
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.