Error description

  • When an update is performed using a Uint64 value ( which is
    only possible using the C# .NET support ), an FFDC exception
    occurs that contains the text "XFError: XDF Error: Fields
    still need serializers".
    The update performs successfully, but the logic that merges
    the previous version of the data with the new value as part of
    the XDF class evoluion support will not be performed.  This
    will mean that all fields that do not exist in the current
    value's version are lost.  If you only have one version of the
    value class that contains the Uint64, then this FFDC message
    can be ignored.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  Users that have an unsigned 64-bit          *
    *                  integer (Uint64) object within a class in   *
    *                  their C# application.                       *
    ****************************************************************
    * PROBLEM DESCRIPTION: When a class                            *
    *                      that contains a unsigned 64-bit         *
    *                      variant object runs an update           *
    *                      operation, the following FFDC message   *
    *                      occurs on the server:                   *
    *                      XDF Error: Fields still need            *
    *                      serializers.                            *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    An eXtreme data format (XDF) serializer was added for C#
    unsigned
    64-bit integers (Uint64).
    

Problem conclusion

  • XDF now correctly serializes and deserializes C# unsigned
    64-bit integer (Uint64) and FFDC messages not generated.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM78827

  • Reported component name

    WS EXTREME SCAL

  • Reported component ID

    5724X6702

  • Reported release

    860

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-12-10

  • Closed date

    2013-06-18

  • Last modified date

    2013-06-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WS EXTREME SCAL

  • Fixed component ID

    5724X6702

Applicable component levels

  • R860 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSTVLU","label":"WebSphere eXtreme Scale"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"860","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
18 June 2013