A fix is available
APAR status
Closed as program error.
Error description
ABENDU0880 REASON CODE C071 on a GHN via secondary index if the secondary index has no active entry. - If a /STA DB is issued before the job run, then the job runs OK once. In a next run it again abends. If there is an active index entry, the abend does not happen. After accessing the database via another secondary index the problem will not occur again on this IMS until it is restarted.
Local fix
n/a
Problem summary
**************************************************************** * USERS AFFECTED: All IMS V12 HALDB PHIDAM users. * **************************************************************** * PROBLEM DESCRIPTION: DFS0832I ABEND U0880 REASON CODE C071 * * occurs on a GHN call issued through a * * secondary index but the secondary * * index has no active entry. * **************************************************************** * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** ABENDU0880 Reason Code C071 occurs on a GHN call via a secondary index when the secondary index has no active entry.
Problem conclusion
GEN: KEYWORDS: *** END IMS KEYWORDS *** The following module has been modified to correct the reported problem: ************ * DFSDLR00 * ************ Code added by apar PM53588 / UK82803 has been modified to check SDBALTSQ of the root level SDB instead of the index SDB to determine if a lock on the ALL X'FF' key segment is needed when a STATUSGE (segment not found) condition is detected.
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
PM78564
Reported component name
IMS V12
Reported component ID
5635A0300
Reported release
201
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-12-06
Closed date
2012-12-20
Last modified date
2013-01-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
DFSDLR00
Fix information
Fixed component name
IMS V12
Fixed component ID
5635A0300
Applicable component levels
R201 PSY UK90543
UP12/12/27 P F212
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.