Error description

  • RAA 6.0.0.10 scanning a particular COBOL file assigns a type
    of Assembler included source to the file, instead of assigning
    a type of COBOL.
    

Local fix

Problem summary

  • RAA's proprietary classification scanner attempts to decide
    what Language a file is based on a combination of format,
    reserved-words and semantics.  It mistook COBOL files,
    especially small ones, as Assembler.
    

Problem conclusion

  • The heuristics now include making sure that small files that
    are not BMS, DBD, or PSB files are well-formed Assembler (have
    at least one assembler label) before classifying them as such.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM78559

  • Reported component name

    RATL ASSET ANAL

  • Reported component ID

    5724V2700

  • Reported release

    600

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-12-05

  • Closed date

    2012-12-14

  • Last modified date

    2012-12-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • wpscobs
    

Fix information

  • Fixed component name

    RATL ASSET ANAL

  • Fixed component ID

    5724V2700

Applicable component levels

  • R600 PSY

       UP



Rate this page:

(0 users)Average rating

Add comments

Document information


More support for:

Rational Asset Analyzer

Software version:

6.0

Reference #:

PM78559

Modified date:

2012-12-14

Translate my page

Machine Translation

Content navigation